CDH_HDH - [source code]

Calculates heating and cooling degree-hours. Degree-hours are defined as the difference between the base temperature and the average ambient outside air temperature multiplied by the number of hours that this difference condition exists. -

Inputs

  • hourlyDryBulbTemperature [Required]
    Annual dry bulb temperature from the Import epw component (in degrees Celsius).
  • coolingBaseTemperature [Default]
    Base temperature for cooling (in degrees Celsius). Default is set to 23.3C but this can be much lower if the analysis is for a building with high heat gain or insulation.
  • heatingBaseTemperature [Default]
    Base temperature for heating (in degrees Celsius). Default is set to 18.3C but this can be much lower if the analysis is for a building with high heat gain or insulation.

Outputs

  • readMe!
    A ummary of the input.
  • hourly_coolingDegHours
    Cooling degree-hours for each hour of the year. For visualizations over the whole year, connect this to the grasshopper chart/graph component.
  • hourly_heatingDegHours
    Heating degree-days for each hour of the year. For visualizations over the whole year, connect this to the grasshopper chart/graph component.
  • daily_coolingDegHours
    Cooling degree-days summed for each day of the year. For visualizations of over the whole year, connect this to the grasshopper chart/graph component.
  • daily_heatingDegHours
    Heating degree-days summed for each day of the year. For visualizations of over the whole year, connect this to the grasshopper chart/graph component.
  • monthly_coolingDegHours
    Cooling degree-days summed for each month of the year.
  • monthly_heatingDegHours
    Heating degree-days summed for each month of the year.
  • annual_coolingDegHours
    The total cooling degree-days for the entire year.
  • annual_heatingDegHours
    The total heating degree-days for the entire year.