Read Annual Result I - [source code]
Read Annual Daylight Results I [Standard Daysim Results] -
Inputs
illFilesAddress [Required]
List of .ill filestestPoints [Required]
List of 3d PointsptsVectors [Optional]
Script variable readDSResultsoccupancyFiles [Optional]
Address to a Daysim occupancy file. You can find some example in \Daysim\occ. Use Honeybee Occupancy Generator to generate a custom occupancy file. You can also use EnergyPlus Schedules directly. If the schedule is using continuous values any value larger than .2 will be considered as occupied.DLAIllumThresholds [Default]
Illuminance threshold for Daylight Autonomy calculation in lux. Default is set to 300 lux.lightingControlGroups [Optional]
Daysim lighting control groups. Daysim can model up to 10 lighting control groups together. Default is > cntrlType = 4, lightingPower = 250, lightingSetpoint = 300, ballastLossFactor = 20, standbyPower = 3, delayTime = 5SHDGroupI_Sensors [Optional]
Senors for dhading group I. Use shadingGroupSensors component to prepare the inputsSHDGroupII_Sensors [Optional]
Senors for dhading group II. Use shadingGroupSensors component to prepare the inputsrunIt [Required]
set to True to run the analysis
Outputs
DLA
Daylight Autonomy > Percentage of the time during the active occupancy hours that the test point receives more daylight than the illuminance threshold.UDLI_Less_100
Useful Daylight illuminance > Percentage of time during the active occupancy hours that the test point receives less than 100 lux.UDLI_100_2000
Useful Daylight illuminance > Percentage of time during the active occupancy hours that the test point receives between 100 and 2000 lux.UDLI_More_2000
Useful Daylight illuminance > Percentage of time during the active occupancy hours that the test point receives more than 2000 lux.CDA
Continuous Daylight Autonomy > Similar to Daylight Autonomy except that the point receives illuminaceLevel/illuminace threshold for hours that illuminance level is less than the threshold.sDA
Spatial Daylight Autonomy > sDA is the percent of analysis points across the analysis area that meet or exceed _DLAIllumThresholds value (set to 300 lux for LEED) for at least 50% of the analysis period. Honeybee doesn't consider the effect of dynamic blinds in calculating sDA.annualProfiles
A .csv file generated by Daysim that can be used as lighting schedule for annual energy simulationhtmReport
Script variable readDSResults